Introduction: Building a Sustainable, Low-Carbon Campus
KITS is actively involved in developing innovative scientific and technological solutions to create a sustainable, green campus. In putting the Sustainable Development Goals (SDGs) into practice, the Karunya Centre for Conservation and Management of Natural Resources (KCCMN) has initiated projects grounded in the “Reduce, Reuse, and Recycle” (3Rs) principles to support a cleaner, greener campus.
The primary objectives of KCCMN are: (i) overall maintenance of campus infrastructure, including buildings, gardens, sports facilities and playgrounds; (ii) maintenance and servicing of generators and other electrical systems, recalibration and refilling of fire extinguishers, provision of fire-safety protocols, and facilitating access for individuals with disabilities, managed by the skilled engineers and technical team from the Construction and Maintenance Department (CMD); and (iii) conducting energy audits to monitor and improve the energy efficiency of conventional and renewable energy sources, with the aim of reducing CO₂ emissions.
The following sections document the measures undertaken to conserve energy and reduce the campus carbon footprint.
| A · At a glance – Energy and carbon management |
| Area | Reported initiative / performance |
|---|---|
| Renewable energy (2024–25) | Total Solar Energy Generated: 1,657,579.71 kWh |
| Solar PV generation | 111,861.71 kWh (95 kW Admin + 20 kW EVR Mess) |
| Solar thermal | 1,545,718.00 kWh equivalent (30 units, 87,600 LPD) |
| Biogas Energy Recovery | 184,836.00 kWh equivalent (17,520 m³/year) |
| Total Campus Renewable Energy | 1,842,415.71 kWh per annum |
| B · Campus energy conservation measures |
1. Usage of solar energy
Renewable energy generated during the reporting year 2024–25 (April 2024–March 2025):
| Renewable-energy source | Energy generated in 2024–25 |
|---|---|
| Solar PV – 95 kW Admin Block | 87,473.71 kWh |
| Solar PV – 20 kW EVR / Oprah Mess Building | 24,388.00 kWh |
| Total Solar PV Generation | 111,861.71 kWh |
| Solar thermal – 87,600 LPD water-heating systems | 1,545,718 kWh |
| Biogas Plants (Waste-to-Energy) | 184,836.00 kWh equiv. |
| Total Campus renewable energy produced | 1,842,415.71 kWh |
2. Conversion to LED lighting
A total of 15,066 conventional tube lights rated at 40 W were systematically converted to 18 W energy-efficient LED tube lights (within an overall institutional deployment of 15,288 LED fixtures). This conversion achieves an annual electricity saving of 861,900 units (kWh), resulting in a recurring financial savings of ₹81,88,050 per annum in institutional electricity charges.
| Parameter | Existing fittings | LED fittings |
|---|---|---|
| Power consumption | 40 W | 18 W |
| Number of fittings | 15,066 | 15,066 |
| Units consumed per day | 4,821 units | 2,169 units |
| Illuminance | 95 lx | 150 lx |
| Units consumed per year | 15,66,825 units | 7,04,925 units |
| Annual EB charges | ₹1,48,84,837 | ₹66,96,787 |
| Maintenance charges/year | ₹45,000 | Replacement warranty up to 3 years |
| Electricity-charge savings/year | ₹81,88,050 | |
| Annual Energy Savings | 8,61,900 kWh / units |
3. Sensors in pumping and water supply
The 36 HP motor used to pump water manually to the overhead tank was converted to a wireless automated water-level controller system. The reported electricity saving is 29,734 units per annum.
4. Other measures to save energy
Motion-sensor lights are provided in the administrative block, corridors and toilets. The Institute also has an Air Quality Sensor Station to monitor air quality.
Water overflow from storage tanks and sumps is controlled using a sensor-based pump operating system. Campus and student-residence sumps are interconnected to support water supply if groundwater levels fall or borewell pumps fail.
Three IoT-enabled automated water controllers have been installed in overhead tanks and sumps; the report states that these save 20% of water and energy.
Capacitors are installed at the load end to maintain unity power factor, with a reported saving of 2,25,000 units per annum.
Water purifiers in all buildings are switched off during holidays to save electricity.
Campus street lights are controlled by timers to switch on according to daylight conditions.
Training programmes are conducted for technicians on energy-saving practices and safety awareness.
| C · Carbon footprint assessment and reporting |
KITS reports its carbon emissions in line with the United Nations Framework Convention on Climate Change. For the reporting year 2024–25, Scope 1 and Scope 2 emissions are reported in tonnes of carbon dioxide equivalent (tCO₂e).
Carbon-emission calculation details reported
| Reporting period | Electricity consumption and reported CO₂ emissions |
|---|---|
| Baseline year – 2015 | 7,417,799 kWh; 4,989.8 tonnes |
| Reporting year – 2024–2025 | 6,207,259 kWh; 4,705.11 tonnes (Scope 1 + Scope 2) |
| D · Solar water heating and solar street lighting |
1. Solar water-heating system
A solar water-heating system with a total installed capacity of 87,600 litres per day (LPD) is installed on campus. The report states that the system saves approximately ₹1 crore in electricity costs per annum.
| Parameter | Reported value |
|---|---|
| Location | Hostel Campus |
| Installed capacity | 87,600 LPD |
| Total kilo calories | 35,04,000 |
| Units saved per day | 4,793 |
| Units saved per month | 1,43,803 |
| Units saved per annum | 15,81,833 |
| Power-saving cost per annum | ₹1,00,44,640 |
Solar water-heating systems in residences – TWINWALL model
| Residence | System capacity | Units | Collector details |
|---|---|---|---|
| Angelina | 3,500 L/day | 2 | Flat-plate; 28 collectors |
| Hephzibah | 2,500 L/day | 3 | Flat-plate; 20 collectors |
| Father Duraisamy | 3,500 L/day | 1 | Flat-plate; 28 collectors |
| Edward George | 2,500 L/day | 2 | Flat-plate; 20 collectors |
| New JVR | 3,500 L/day | 2 | Flat-plate; 28 collectors |
| New JMR | 3,500 L/day | 2 | Flat-plate; 28 collectors |
| New BRR | 3,500 L/day | 2 | Flat-plate; 28 collectors |
| New Bethany | 3,500 L/day | 2 | Flat-plate; 28 collectors |
The TWINWALL systems use natural-gravity circulation. The stated space requirement is 60 m² for a 3,500 LPD system and 45 m² for a 2,500 LPD system. The application is hot water; auxiliary heating is provided by a 4 kW electrical supply with thermostat. Tanks are provided with air vents and mounted on concrete floors using steel frames and anchoring bolts.
Solar water-heating systems in residences – VESAT model
| Residence | Capacity | Units | Collector / system details |
|---|---|---|---|
| Sevugapandian | 3,500 L/day | 2 | Flat-plate; 28 collectors |
| Sundararaj | 3,500 L/day | 2 | Flat-plate; 28 collectors |
| P. R. Garg | 500 L/day | 1 | Flat-plate; 28 collectors |
| Dakshinamoorthy | 3,500 L/day | 1 | Flat-plate; 28 collectors |
| Oprah | 3,500 L/day | 1 | Flat-plate; 28 collectors |
| Evangeline | 3,500 L/day | 2 | Flat-plate; 28 collectors |
The VESAT systems use natural-gravity circulation and are intended for hot-water applications. The report specifies auxiliary heating through a 4 kW electrical supply with thermostat, insulated stainless-steel storage tanks with glass-wool insulation and aluminium cladding, and concrete-floor mounting with steel frames and anchoring bolts.
2. Solar street lighting
Seven solar street lights are installed on the Karunya campus. All seven are reported to be working.
| Installation location | Panel type | Number of lights | Condition |
|---|---|---|---|
| Guest House | Crystalline type | 4 | Working |
| Opposite to S&H Auditorium | Crystalline type | 2 | Working |
| Mechanical Building Yard | Crystalline type | 1 | Working |
Solar street-light specifications
| Component | Parameter | Specification |
|---|---|---|
| PV module | Panel / cell type | Crystalline; high-efficiency solar cells |
| PV module | Nominal capacity | 1 × 120 W |
| PV module | Peak power voltage / current | 16.2 V / 8.3 A |
| PV module | Tolerance | ±5% |
| Mechanical | Front cover glass | Toughened glass |
| Mechanical | Encapsulate | Ethylene Vinyl Acetate (EVA) |
| Mechanical | Mounting frame | Anodized aluminium channel |
| Mechanical | Rear panel / junction box | Polyvinyl Fluoride (PVF) / ABS moulded box |
| Mechanical | Weight | 5.4 kg |
| Battery | Normal capacity / voltage | 100 Ah / 12 V |
| Battery | Rated discharge current | C/10 |
| Battery | Self-discharge / expected life | About 0.5% per week / about 1,500 cycles |
| Battery | Type / construction | Low-maintenance lead acid; 12 V block |
| Battery | Container material | Polypropylene |
| Controller | Charge-controller type and rating | Series Pulsed Two Step; 15 A maximum |
| Cable assembly | Module to controller | 4.0 mm² cable with ring terminal |
| Cable assembly | Luminary to controller | 1.5 mm² dual-sheathed cable |
| Cable assembly | Battery to lighting | 4.0 mm² cable with ring and fork terminal |
| E · Grid-tied solar power plants |
1. 95 kW grid-tied solar power plant – Admin Block
The 95 kW grid-tied solar PV plant was installed on 1 July 2016 in the Admin Block. It uses polycrystalline solar panels. Approximately 312 panels are connected through four inverters to the distribution board, from which power is supplied to the load. Power generation is monitored online through the inverters.
| Feature | Reported specification |
|---|---|
| Plant type and capacity | Grid-tied 95 kW polycrystalline PV plant |
| Inverters | 4 × 25 kW; SMA make |
| Strings | 4 strings in each inverter |
| Panel configuration | 84 panels per inverter, except the fourth inverter with 60 panels |
| PV modules | 312 modules, each rated 310 W; EMMVEE make |
| Reported generation | 87,473.71 kWh (Admin Block plant entry) |
2. 20 kW grid-tied solar power plant – EVR / Ladies Hostel
A 20 kW grid-tied polycrystalline PV plant is installed at the EVR Block / Ladies Hostel building.
| Feature | Reported specification |
|---|---|
| Plant type and capacity | Grid-tied 20 kW polycrystalline PV plant |
| Inverter | 1 inverter; 25 kW capacity; SMA make |
| Strings | 4 strings |
| Panel configuration | 66 panels stated in the source |
| PV modules | 16 modules, each rated 310 W; EMMVEE make (as stated in the source) |
| Reported generation | 24,388 kWh (EVR / Oprah Mess Building plant entry) |
The source lists both 66 panels and 16 modules for this plant. Both values are retained as documented and should be checked against the plant commissioning or asset records.
| F · Biogas and resource recovery |
A biogas plant is a decentralised energy system that can support self-sufficiency in heat and power while reducing environmental pollution. Biogas is a mixture of carbon dioxide (CO₂) and methane (CH₄), generated when organic compounds undergo fermentation in the absence of air (anaerobic fermentation). Organic matter such as human or animal manure is used to feed the plant.
As a residential campus, KITS treats night soil and food waste generated in student residences in biogas plants installed at the locations listed below. Another wastewater-management initiative in student residences involves replacing septic tanks with four biogas plants. These plants reportedly generate 114 kg/day of cooking gas, reducing the residences’ consumption of LPG. The LPG displacement is reported qualitatively; a quantified CO₂ reduction requires LPG purchase/displacement records and an agreed emissions factor.
| Location | Plant capacity | Year of installation | Plant cost (₹ lakh) | LPG cylinders saved (19 kg/day) |
|---|---|---|---|---|
| FDR Campus | 100 m³ | 2017 | 32.0 | 2 |
| JMR Campus | 80 m³ | 2010 | 26.0 | 2 |
| Ladies Hostel (PRG Campus) | 100 m³ | 2017 | 32.0 | 2 |
| Ladies Hostel (EVR Campus) | 80 m³ | 2017 | 26.0 | 1.5 |
The treated effluent from the biogas plant is diverted to the sewage treatment plant (STP) for storage and use in irrigation and gardening. The report states that this reduces the organic load reaching two STPs, with capacities of 6 lakh litres and 4.5 lakh litres, and reduces their operation and maintenance costs.
| G · Summary |
For 2024–25, KITS reports Scope 1 and Scope 2 emissions of 4,705.11 tCO₂e. Alongside conventional electricity and transport-related emissions, the institution has implemented solar PV, solar thermal, biogas and energy-efficiency measures. Estimated avoided emissions from electricity displacement and energy savings are presented separately below, using the 0.84 kg CO₂/kWh conversion factor stated in the original 7.2.3 document. These estimates should not be added to the reported emissions total; they represent an indicative counterfactual avoided-emissions calculation.
| H · 2024–25 CO₂ Emissions and Estimated Avoided Emissions |
The following table separates reported emissions from conventional energy use and indicative avoided emissions attributable to renewable-energy generation and energy-efficiency measures. Avoided emissions are estimated using the 0.84 kg CO₂/kWh factor.
| Category | 2024–25 energy / activity data | CO₂ emissions / avoided emissions | Basis and remarks |
|---|---|---|---|
| Conventional electricity | 6,207,259 kWh consumed | 4,636.82 tCO₂e emitted | Reported 2024–25 electricity emissions; institutional GHG record |
| Vehicles | Buses and cars | 68.29 tCO₂e emitted | Difference between total Scope 1+2 (4,705.11 t) and electricity (4,636.82 t) |
| Total conventional emissions | Scope 1 + Scope 2 | 4,705.11 tCO₂e emitted | Official institutional reporting-year total; not a calculated counterfactual |
| Solar PV | 111,861.71 kWh | 93.96 tCO₂e estimated avoided | (111,861.71 × 0.84) / 1,000; includes projected CTC and EGR generation |
| Solar thermal | 1,545,718 kWh generated | 1,298.40 tCO₂ estimated avoided | (1,545,718 × 0.84) / 1,000 |
| Energy-efficient appliances / measures | 4,247,020 kWh/year | 3,567.50 tCO₂ estimated avoided | (4,247,020 × 0.84) / 1,000; reported annual saving from the institutional energy-generation/efficiency record |
| Total quantified avoided emissions | Solar PV + solar thermal + energy efficiency | 4,959.86 tCO₂e estimated avoided | Excludes biogas; arithmetic total only. Potential overlap in energy-savings categories and projections must be resolved before reporting a net figure. |
| Indicative arithmetic balance | Reported Scope 1 + Scope 2 Baseline Emissions: 4,705.11 tCO₂e | Quantified Avoided Emissions: 4,959.86 tCO₂e Net Avoided Balance: -254.75 tCO₂e | Net Emission |